Hach DR3900 Spektralphotometer mit RFID-Technologie
ArtikelnummerLPV440.99.00001
MengeneinheitStück
DR3900 Spectrophotometer with RFID technology
Wavelength accuracy: ± 1.5 nm (wavelength range 340 - 900 nm)
Wavelength range: 320 - 1100 nm
Includes:
Spectrophotometer DR3900, adapter "A" for 1" round + Accuvac/1 cm rectangular cuvettes, manual in 5 languages (GB, D, F, I, E), power supply 100 - 240V, 47 - 63Hz, Operator RFID Tag.
Expert water analysis made simple.
High-performance VIS spectrophotometer with RFID technology for reliable and traceable measurement results of routine analysis and user applications.
Compact and reliable VIS spectrophotometer with reference beam technology. Samples are traced back to sample location due to RFID technology. Lot number and expiry date information of reagents are now included on the 2D barcode. The RFID module reads out and displays all batch specific information from cuvette test box. The batch certificate can be printed out immediately via the spectrophotometer.
The RFID module makes method updates quick, convenient and easy as well.
Process results can be compared to laboratory reference values in the photometer via LINK2SC connection between SC controller and photometer. Data can be exchanged bi-directionally via Ethernet, i.e. matrix corrections of process probes can be done directly from the laboratory.
Simple preparation
Fast execution
Comprehensive documentation
Simple preparation
The boxes and cuvettes are colour-coded for fast and easy parameter and range recognition. Step-by-step illustrated test methods are printed on the box as quick reference or can be called up in the instrument menu.
The DR3900 spectrophotometer uses RFID technology to enable reliable communication with the sample taker and the samples. Simply hold the bottle lable in front of the RFID* sensor. When evaluating the cuvette test, use the tool bar on the touchscreen to assign the result to the sample.
Fast execution
The new 2D barcode details the batch number and the expiry date of the reagents. During the measurement process the DR3900 immediately picks up all the information on the cuvette by using the IBR+ barcode reader. If the expiry date has already passed, an automatic warning will be issued.
Method updates are also identified by the 2D barcode. The calibration data is incorporated in the RFID* tag on the box for hands-free update with the RFID module.
Comprehensive documentation
Measurement results are documented on the detailed level with timestamp, operator ID, absorbance reading, and calculated concentration. The 2D barcode delivers the lot number and expiry date, logged with every result. For your accreditation the certificate of analysis can be called up just by wiping the reagent box towards the RFID* sensor.
*RFID technology available in all EU countries plus e.g. Norway, Switzerland, Serbia, Macedonia, Turkey, Russia et al. For other countries please ask your local Hach contact person.
Beam Height: 10 mm
Cuvette compatibility: Rectangular: 10, 20, 30, 50 mm, 1 inch; round: 13 mm, 1 inch
Data storage: 2000 measured values (Result, Date, Time, Sample ID, Operator ID)
Dimensions (H x W x D): 151 mm x 350 mm x 255 mm
Display: 7" TFT WVGA colour touchscreen
Enclosure waterproof rating: IP30
IBR+: Automatic test recognition, lot control and expiry date check
Includes: Includes: Spectrophotometer DR3900, adapter "A" for 1" round + Accuvac/1 cm rectangular cuvettes, manual in 5 languages (GB, D, F, I, E), power supply 100 - 240V, 47 - 63Hz, Operator RFID Tag.
Interfaces: USB type A (2), USB type B, Ethernet, RFID module
Light source: Gas-filled Tungsten (visible)
LINK2SC: Data exchange with SC1000 controller
Manual languages: German, English, French, Italian, Spanish, Portuguese (PT), Czech, Danish, Dutch, Hungarian, Polish, Romanian, Russian, Slovenian, Swedish, Turkish, Greek, Finnish, Croatian, Bulgarian, Serbian, Slovakian
Max. operating humidity: 80 %
Max. Storage Humidity: 80 %
Operating conditions: 10 °C - 40 °C
Operating mode: Transmittance (%), Absorbance and Concentration, Scanning
Optical system: Reference beam, spectral
Photometric accuracy: 1 % at 0.50 - 2.0 Abs
5 mAbs @ 0.0 - 0.5 Abs
Photometric linearity: < 0.5 % - 2 Abs
≤ 1 % at >2 Abs with neutral glass at 546 nm
Photometric measuring range: ± 3.0 Abs (wavelength range 340 - 900 nm)
Power requirements (Hz): 50/60 Hz
Power requirements (Voltage): 110 - 240 V AC
Power Supply: Desk Power Supply
Power supply: External power supply, 100 - 240 V, 50 - 60 Hz
Pre-programmed methods: > 220
Printer compatibility: Supports most office deskjet printers
Quality assurance: Function to schedule and document QA with pass/fail indication
Specific Technology: RFID for easy method update, sample ID and Certificate of Analysis
Storage conditions: -30 °C - 60 °C
Stray light: < 0.1 % T at 340 nm with NaNO2
User interface: Bulgarian, Chinese, Croatian, Czech, Danish, Dutch, English, Finnish, French, German, Greek, Hungarian, Italian, Japanese, Korean, Polish, Portuguese - Brasilian, Portuguese, Russian, Serbian, Slovakian, Slowenian, Spanish, Swedish, Turkish
User programmes: 100
Warranty: 2 years
Wavelength accuracy: ± 1.5 nm (wavelength range 340 - 900 nm)
Wavelength calibration: Automatic
Wavelength range: 320 - 1100 nm
Wavelength reproducibility: ± 0.1 nm
Wavelength resolution: 1 nm
Wavelength selection: Automatic
Weight: 4.2 kg